Level 5 Floor Plan — Guest Rooms 512–513
Review required
Door tag, swing and position on the floor plan
D-101 can sit anywhere on the 6,000 mm south wall of R-512. Every millimetre was solved; move along the strip and the plan above is recomputed at each position.
2,803mm
Strikes console F-07 after 15.7° of opening.
Hover or drag the strip. ← → 10 mm · Shift 100 mm · Alt 1 mm · Page Up Page Down next boundary · Home End
The approved plan and two proposals, measured by the same engine with the same settings. Revision A strikes console F-07 after 15.7°. Revision B clears it by 391.5 mm and still puts 3 drawings under review.
Opens the full 90° without touching furniture.
1,700 mmbaseline
90.0°of 90°
1,083.7 mmclear
None
Approved baselineREV-0 · in force
Strikes console F-07 after 15.7° of opening.
3,000 mm+1,300 mm
15.7°of 90°
188.7 mmintrusion
3 to reviewA-101 · A-401 · D-01
Rejected· Sample reviewer“Leaf strikes console F-07 after 15.7°.”RCPT-99B110A8-RA
Opens the full 90° without touching furniture.
2,400 mm+700 mm
90.0°of 90°
391.5 mmclear
3 to reviewA-101 · A-401 · D-01
Accepted· Sample reviewer“Full swing clear. Reissue the flagged sheets.”RCPT-BA406D1D-AB
At 2,400 mm, D-101 clears F-07 by 391.5 mm. The door still moved 700 mm, so every sheet linked to it is flagged for a person to revise and re-issue. PLANRIFT marks them; it never edits them.
Level 5 Floor Plan — Guest Rooms 512–513
D-101 hinge position 1,700 mm → 2,400 mm (+700 mm)Door tag, swing and position on the floor plan
Review required
Interior Elevations — Room 512
D-101 hinge position 1,700 mm → 2,400 mm (+700 mm)South wall elevation: opening position and size
Review required
Door Schedule — Level 5
D-101 hinge position 1,700 mm → 2,400 mm (+700 mm)Schedule row D-101: size, type, handing, location
Review required
No record for R-513 or A-402 Interior Elevations — Room 513. Only sheets linked to the element that changed are flagged.
PLANRIFT · revision receipt
RCPT-BA406D1D-AB
Aster House Hotel — Guest Room Revision
Scenario B · Door at 2,400 mm
planrift-geometry/1.0.0
A review record, not a construction certificate or a compliance statement.
The work ran through 5 specs (38 of 49 tasks done), 9 steering files and 7 custom agents. 6 hooks decide what the agent may do on its own. This page reads them from .kiro/ when it is built.
SessionStartSession starts
Resume summary from the repository
session-resume
node scripts/kiro/session-status.mjsPreTaskExecSpec task starts
Types must pass first
task-start-gate
node scripts/kiro/run-check.mjs typecheck --blockPreToolUseAgent writes a file
Credentials are blocked
secret-guard
node scripts/kiro/secret-guard.mjsPostFileSaveAgent edits src/domain
Geometry tests run
geometry-regression
node scripts/kiro/run-check.mjs test:domainPreToolUseShell: deploy or push
Asks you first
public-action-guard
node scripts/kiro/public-action-guard.mjsPostTaskExecSpec task ends
Typecheck · lint · tests
task-completion-gate
node scripts/kiro/run-check.mjs typecheck lint test --format-changedThe engine solves single-leaf door swings against rectangular furniture in whole millimetres. Anything outside that model is reported as Unsupported, never guessed, and nothing here is a compliance or approval tool.
Rectangular rooms
Axis-aligned rooms with wall thickness per side, in whole millimetres.
Single-leaf hinged doors
A 90° inward swing, tested at every whole-millimetre hinge position.
Rectangular furniture
Unrotated footprints, checked against the full swept sector.
Scenarios, comparison, receipts
Branch from the approved revision, compare side by side, record the decision.
Exports
Project JSON, impact ledger CSV, printable HTML receipt, plan SVG.
Code, accessibility or egress compliance
Clearances describe the modelled geometry only.
Approval to build
A receipt records a review. It is not a certificate.
DWG, DXF, IFC or Revit
No CAD or BIM import or export.
Automatic drawing edits
Flagged sheets are revised and re-issued by the design team.
Rotated furniture, sliding doors, 3D clash
Reported as Unsupported, never guessed.
furniture.unsupported-rotationdoor.unsupported-operation
The studio opens on this project: two guest rooms, two doors and four issued sheets. Try a position, compare it with the approved plan and record the decision. It all runs in your browser; nothing is uploaded.